Millipore Sigma Vibrant Logo
Attention: We have moved. EMD Millipore products are no longer available for purchase on emdmillipore.com.Learn More

CTGB73TP3 Aerex CTGB Cartridge Filter 30 in. 0.2 µm Code 7

View Products on Sigmaaldrich.com
CTGB73TP3
3  Double Easy-Open bag
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue NumberCTGB73TP3
Trade Name
  • Aerex®
DescriptionAerex CTGB Cartridge Filter 30 in. 0.2 µm Code 7
References
Product Information
HS Code8421 29 90
Device ConfigurationCartridge
Maximum Differential Pressure, bar (psid)Forward: 6.9 bar (100 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 145 °C. Reverse: 5.2 bar (75 psid) @ 25 °C, intermittent
Maximum Inlet Pressure, bar (psi)Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 145 °C; Reverse - 5.2 bar (75 psi) @ 25 °C
Cartridge CodeCode 7
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
MediaAerex®
Sterilization200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
Bacterial Grow-ThroughThe membrane has been qualified to retain bacteria when challenged for 21 days with a minimum Brevundimonas diminuta aerosol concentration of 1 x 10⁷ CFU/cm².
WettabilityHydrophobic
Physicochemical Information
Pore Size0.2 µm
Bubble Point at 23 °C≥900 mbar (13 psig) nitrogen with 60/40 % IPA/water
Gravimetric ExtractablesThe extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
HydroCorr≤0.40 mL/min per 10-inch cartridge with water @ 1380 mbar (20 psig)
Nitrogen Diffusion at 23 °C≤45 mL/min @ 690 mbar (10 psig) in 60/40 % IPA/water
Non-Fiber ReleasingThis product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Virus Aerosol RetentionThis product has been qualified to retain a ΦX174 virus aerosol challenge of 10⁸ to 10¹⁰ PFU at an air flow rate of 50 SCFM per 10-inch cartridge after 50 steam-in-place cycles at 145 °C.
USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Dimensions
Cartridge Nominal Length30 in. (75 cm)
Diameter6.9 cm (2.7 in.)
Filtration Area1.95 m²
Device Size30 in.
Materials Information
Chemistry
  • Polytetrafluoroethylene (PTFE)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Support MaterialPolypropylene
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size3
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalog Number GTIN
CTGB73TP3 04053252489624

Documentation

Aerex CTGB Cartridge Filter 30 in. 0.2 µm Code 7 SDS

Title

Safety Data Sheet (SDS) 

Certificates of Quality

Title
AEREX CARTRIDGE C2SB55356
Aerex Cartridge C0EB42396
Aerex Cartridge C7SA07794
Aerex Cartridge C8MA33534
Aerex Cartridge C9KA68812
Aerex Cartridge - C0BB25334
Aerex Cartridge - C7JA37625
Aerex Cartridge - C8EA77412
Aerex Cartridge C1MB70002
Aerex Cartridge C3CB08160

Technical Info

Title
Steam Sterilization & Integrity Testing Procedures

Data Sheet

Title
Aerex®Cartridge Filters

User Guides

Title
Visual Inspection Guide