Millipore Sigma Vibrant Logo
Attention: We have moved. EMD Millipore products are no longer available for purchase on emdmillipore.com.Learn More

CTGR01TP1 Aervent CTGR Cartridge Filter 10 in. 0.2 µm Code 0

View Products on Sigmaaldrich.com
CTGR01TP1
1  Double Easy-Open bag
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue NumberCTGR01TP1
Trade Name
  • Aervent®
DescriptionAervent CTGR Cartridge Filter 10 in. 0.2 µm Code 0
References
Product Information
HS Code8421 39 90
Device ConfigurationCartridge
Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.8 bar (25 psid) @ 80 °C. Reverse: 4.1 bar (60 psid), intermittent
Maximum Inlet Pressure, bar (psi)Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; Reverse - 4.1 bar (60 psi), Intermittent
Cartridge CodeCode 0
Quality LevelMQ400
Applications
Biological Information
MediaAervent®
Sterilization150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
Bacterial Grow-ThroughRetains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²
Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
WettabilityHydrophobic
Physicochemical Information
Pore Size0.2 µm
Bubble Point at 23 °C≥1100 mbar (16 psig) nitrogen with 70/30 % IPA/water
Gravimetric ExtractablesThe extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
HydroCorr≤0.75 mL/min @ 2.6 bar (38 psig) per 10 in cartridge
Nitrogen Diffusion at 23 °C≤24 mL/min @ 970 mbar (14 psig) in 70/30 % IPA/water
Non-Fiber ReleasingThis product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Virus Aerosol RetentionRated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.
USP Bacterial EndotoxinsAqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Dimensions
Cartridge Nominal Length10 in. (25 cm)
Diameter6.9 cm (2.7 in.)
Filtration Area0.65 m²
Device Size10 in.
Materials Information
Chemistry
  • Polytetrafluoroethylene (PTFE)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Support MaterialPolypropylene
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size1
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalog Number GTIN
CTGR01TP1 04053252346811

Documentation

Aervent CTGR Cartridge Filter 10 in. 0.2 µm Code 0 SDS

Title

Safety Data Sheet (SDS) 

Certificates of Quality

Title
Aerex Cartidge C7PA76483
Aervent Cartridge C8SA67265
Aervent Cartridge C0AB89437
Aervent Cartridge C1CB13888
Aervent Cartridge C7KA37626
Aervent Cartridge C7PA76822
Aervent Cartridge C8BA23452
Aervent Cartridge C8BA28950
Aervent Cartridge C9JA63039
Aervent Cartridge C9SA84033

Technical Info

Title
Bubble Point Test Method Using Aervent 0.2 µm Hydrophobic Membrane with 60/40 IPA

Data Sheet

Title
Sterilizing-Grade Aervent®Filters