Millipore Sigma Vibrant Logo
Attention: We have moved. EMD Millipore products are no longer available for purchase on emdmillipore.com.Learn More

CTGR02TP1 Aervent CTGR Cartridge Filter 20 in. 0.2 µm Code 0

View Products on Sigmaaldrich.com
CTGR02TP1
1  Double Easy-Open bag
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue NumberCTGR02TP1
Trade Name
  • Aervent®
DescriptionAervent CTGR Cartridge Filter 20 in. 0.2 µm Code 0
References
Product Information
HS Code8421 99 99
Device ConfigurationCartridge
Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.8 bar (25 psid) @ 80 °C. Reverse: 4.1 bar (60 psid), intermittent
Maximum Inlet Pressure, bar (psi)Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; Reverse - 4.1 bar (60 psi), Intermittent
Cartridge CodeCode 0 (2-222) O-rings
Quality LevelMQ400
Applications
Biological Information
MediaAervent®
Sterilization150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
Bacterial Grow-ThroughRetains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²
Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
WettabilityHydrophobic
Physicochemical Information
Pore Size0.2 µm
Bubble Point at 23 °C≥1100 mbar (16 psig) nitrogen with 70/30 % IPA/water
Gravimetric ExtractablesThe extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
HydroCorr≤1.5 mL/min @ 2.6 bar (38 psig) per 20 in cartridge
Nitrogen Diffusion at 23 °C≤48 mL/min @ 970 mbar (14 psig) in 70/30 % IPA/water
Non-Fiber ReleasingThis product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Virus Aerosol RetentionRated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.
USP Bacterial EndotoxinsAqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Dimensions
Cartridge Nominal Length20 in. (51 cm)
Diameter6.9 cm (2.7 in.)
Filtration Area1.3 m²
Device Size20 in.
Materials Information
Chemistry
  • Polytetrafluoroethylene (PTFE)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Support MaterialPolypropylene
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size1
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalog Number GTIN
CTGR02TP1 04053252487453

Documentation

Aervent CTGR Cartridge Filter 20 in. 0.2 µm Code 0 SDS

Title

Safety Data Sheet (SDS) 

Certificates of Quality

Title
Aervent Cartridge - C7DA97139
Aervent Cartridge - C8PA59656
Aervent Cartridge C0AB15469
Aervent Cartridge C2BB38296
Aervent Cartridge C3BB81742
Aervent Cartridge C3BB88795
Aervent Cartridge C3KB57278
Aervent Cartridge C3MB60534
Aervent Cartridge C3PB64813
Aervent Cartridge C3SB69464

Technical Info

Title
Bubble Point Test Method Using Aervent 0.2 µm Hydrophobic Membrane with 60/40 IPA

Data Sheet

Title
Sterilizing-Grade Aervent®Filters