Millipore Sigma Vibrant Logo
Attention: We have moved. EMD Millipore products are no longer available for purchase on emdmillipore.com.Learn More

Amicon® Ultra-4 Centrifugal Filter Units

Provide both ultra-fast spin times and ultra-high recoveries

Overview

Specifications

Ordering Information

Amicon® Ultra-4 Centrifugal Filter UnitsClear Sorting & Filtering Show Filter
Catalog NumberDescriptionNMWLPack Size
UFC800308Amicon® Ultra-4 Centrifugal Filter Unit 3 KDa 8
UFC800324Amicon® Ultra-4 Centrifugal Filter Unit 3 KDa 24
UFC800396Amicon® Ultra-4 Centrifugal Filter Unit 3 KDa 96
UFC801008Amicon® Ultra-4 Centrifugal Filter Unit 10 KDa 8
UFC801024Amicon® Ultra-4 Centrifugal Filter Unit 10 KDa 24
UFC801096Amicon® Ultra-4 Centrifugal Filter Unit 10 KDa 96
UFC803008Amicon® Ultra-4 Centrifugal Filter Unit 30 KDa 8
UFC803024Amicon® Ultra-4 Centrifugal Filter Unit 30 KDa 24
UFC803096Amicon Ultra-4 Centrifugal Filter Unit 30 KDa 96
UFC805008Amicon®Ultra-4 Centrifugal Filter Unit 50 KDa 8
UFC805024Amicon® Ultra-4 Centrifugal Filter Unit 50 KDa 24
UFC805096Amicon Ultra-4 Centrifugal Filter Unit 50 KDa 96
UFC810008Amicon® Ultra-4 Centrifugal Filter Unit 100 KDa 8
UFC810024Amicon® Ultra-4 Centrifugal Filter Unit 100 KDa 24
UFC810096Amicon® Ultra-4 Centrifugal Filter Unit 100 KDa 96

Amicon® Ultra-4 Filter Units are assembled with centrifuge tubes and caps.
The Amicon® Ultra-4 with Ultracel®-10 membrane is CE marked.

Back To Top

Amicon® Ultra-4 Centrifugal Filter Units, registered for IVD useClear Sorting & Filtering Show Filter
Catalog NumberDescriptionNMWLPack Size
UFC801008DAmicon® Ultra-4 Centrifugal Filter Unit 10 KDa 8
UFC801024DAmicon® Ultra-4 Centrifugal Filter Unit 10 KDa 24
UFC801096DAmicon® Ultra-4 Centrifugal Filter Unit 10 KDa 96

Back To Top

Documentation

References

Reference overviewApplication
Modification of Allergenicity and immunogenicity of formate dehydrogenase by conjugation with linear mono methoxy poly ethylene glycol: Improvement in detoxification of formate in methanol poisoning
Muthuvel A., Rajamani R., Senthilvelan M., Manikandan s., Sheeladevi R.
Clinica Chimica acta 374 (2006) 122-128  2006

Protein Purification
Simultaneous reduction and alkylation of protein disulfides in a centrifugal ultrafiltration device prior to two-dimensional gel electrophoresis.
Smejkal GB, Li C, Robinson MH, Lazarev AV, Lawrence NP, Chernokalskaya E.
J Proteome Res. 2006 Apr;5(4):983-7.  2006

Protein Concentration
Measurement of Pro-C-Type Natriuretic Peptide in Plasma
Nielsen, S.J., Rehfeld, J.F., Pedersen, F., Kastrup, J., Videback, R., Goetze, J.P.
Clinical Chemistry 51 (2005): 2173-2716  2005

Comparative Proteomic Analysis of Intra- and Interindividual Variation in Human Cerebrospinal Fluid
Hu, Y., Malone, J.P., Fagan, A.M., Townsend, R.R., Holtzmann, D.M
Molecular & Cellular Proteomics 4.12 (2005): 2000-2009  2005

Ultrafiltration for proteomic sample preparation
E. Chernokalskaya, S. Gutierrez, A.M. Pit, J. T. Leonard
Electrophoresis, 25: 2461-2468  2004

Sample Prep

FAQ

QuestionAnswer
Amicon Ultra units are offered in what volumes?Amicon Ultra units are available in 0.5 mL, 4mL & 15ml volumes.
What is the recommended rotor for Amicon Ultra units?Any rotor capable of accommodating 22.7 cm in diameter and 124 mm length centrifuge tubes for the Amicon Ultra-4 and 35 mm in diameter and 121 mm in length for the Amicon Ultra-15 can be used for Amicon Ultra units.
How should I select the appropriate Molecular Weight Cutoff (MWCO) for Amicon Ultra?Select a Molecular Weight Cutoff that is 2x smaller that the Molecular Weight (MW) of the solute of interest.
Which membranes are available in Amicon Ultra units?Amicon Ultra units are only available with Ultracel regenerated cellulose material. This high recovery/low binding membrane is offered in 3,000, 10,000, 30,000, 50,000 & 100,000 MWCO.
Can the Amicon Ultra be spun to dryness?No, the Amicon Ultra has a built in deadstop.
Can the Amicon Ultra be used with nucleic acids?Yes, Amicon Ultra units have been evaluated for use with Genomic and PCR fragments. The 30 kDa MWCO provides the best balance between recovery and spin time. Protocols related to Genomic and PCR fragments can be found in the user guide.
What is the maximum sample volume for Amicon Ultra?
Amicon Ultra-4Amicon Ultra-15
Swinging Bucket4ml 15ml
Fixed Angle4ml(35 & 45 degree rotor angle)12ml(35 degree rotor angle)
3.5ml(23 degree rotor angle)
What is the maximum centrifugal force I can spin Amicon Ultra-4 & Amicon Ultra-15?
4ml15ml
Swinging Bucket4000 x g4000 x g
3500 x g for concentrated/viscous solutions
Fixed Angle(23, 35 &45 degrees)7500 x g5000 x g
What is the chemical compatibility of Amicon Ultra?Amicon Ultra units are intended for use with biological fluids and aqueous solutions. Please refer to the user guide, catalogue, or contact Technical Support.
Can Amicon Ultra units be sterilized with ethanol?Amicon Ultra is compatible with 70% Ethanol, but we have not done any studies to test for sterilization.