1461-90005 General sampling, Accurate Volume application, 5 mL

View Products on Sigmaaldrich.com
1461-90005
50  
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue Number1461-90005
Trade Name
  • NovaSeptum®
DescriptionGeneral sampling, Accurate Volume application, 5 mL
References
Product Information
Device ConfigurationSingle sampling
Fitting InletSeptum unit with a 1 mm needle
Fitting OutletFemale or Male Luer in PVDF
Maximum Sampling Pressure0.5 bar (7.25 psi)
Maximum Operating TemperatureSingle 5mL: -80 to 134 °C (-112 to 273 °F)
Quality LevelMQ400
Applications
ApplicationSterility testing, pyrogenic testing, endotoxin testing, chemical analysis, pH analysis, and fermentation applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤2.15 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
SterilitySterile
SterilizationBeta Irradiation (e-beam) minimum 25 kGy according to ISO 11137 TIR No. 27
Physicochemical Information
Dimensions
Needle Size1.0 mm
Volume5 mL
Materials Information
Device Material
  • Syringe: polycarbonate, medical grade, platinum-cured silicone, medical silicone fluid
Tubing MaterialMedical grade, platinum-cured silicone
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Animal Origin MaterialsPlease refer to the Animal Origin Statement
Storage and Shipping Information
Packaging Information
Bag MaterialDrainage bag: polyethylene film
Material Size50
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalog Number GTIN
1461-90005 04053252479533

Documentation

Certificates of Quality

Title
NOVASEPTUM? ACCURATE VOLUME APPLICATION - 210812-502
NOVASEPTUM? ACCURATE VOLUME APPLICATION - 211006-505
NOVASEPTUM? ACCURATE VOLUME APPLICATION - 211027-503
NOVASEPTUM® ACCURATE VOLUME APPLICATION - 200226-502
NOVASEPTUM® ACCURATE VOLUME APPLICATION- 160704-503
NOVASEPTUM® ACCURATE VOLUME APPLICATION - 200908-501
NOVASEPTUM® ACCURATE VOLUME APPLICATION - 160219-504
NOVASEPTUM® ACCURATE VOLUME APPLICATION - 160307-507
NOVASEPTUM® ACCURATE VOLUME APPLICATION - 160405-508
NOVASEPTUM® ACCURATE VOLUME APPLICATION - 160511-506

Related Products & Applications

Product Families

Categories

Small Molecule Pharmaceuticals > Purification of Pharm Drugs > Sterile Sampling > NovaSeptum
Small Molecule Pharmaceuticals > API Synthesis > Sterile Sampling > NovaSeptum
Biopharmaceutical Manufacturing > Formulation > Sterile Sampling > NovaSeptum
Biopharmaceutical Manufacturing > Upstream Processing > Sterile Sampling (NovaSeptum) > NovaSeptum
Biopharmaceutical Manufacturing > Harvest > Sterile Sampling > NovaSeptum
Biopharmaceutical Manufacturing > Downstream Processing > Sterile Sampling > NovaSeptum
Biopharmaceutical Manufacturing > Drug Substance > Sterile Sampling > NovaSeptum