110983 N,N-Dimethylformamide

Overview

Replacement Information

Key Specifications Table

CAS #EC NumberHill FormulaChemical FormulaMolar Mass
68-12-2200-679-5C₃H₇NOHCON(CH₃)₂73.09 g/mol

Products

Catalog NumberPackaging Qty/Pack
1109831000 Glass bottle 1 l
1109832500 Glass bottle 2.5 l
Description
Catalogue Number110983
SynonymsDMF, N,N-Dimethylmethanamide, Formic acid dimethylamide
DescriptionN,N-Dimethylformamide
OverviewSupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionization detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
References
Product Information
CAS number68-12-2
EC index number616-001-00-X
EC number200-679-5
Hill FormulaC₃H₇NO
Chemical formulaHCON(CH₃)₂
Molar Mass73.09 g/mol
HS Code2924 19 22
Structure formula ImageStructure formula Image
Quality LevelMQ100
Applications
ApplicationN,N-Dimethylformamide for gas chromatography ECD and FID SupraSolv®. CAS 68-12-2, EC Number 200-679-5, chemical formula HCON(CH₃)₂.
Biological Information
Physicochemical Information
Boiling point153 °C (1013 hPa)
Density0.944 g/cm3 (25 °C)
Explosion limit2.2 - 16 %(V)
Flash point57.5 °C
Ignition temperature410 °C
Melting Point-61 °C (External MSDS)
pH value7 (200 g/l, H₂O, 20 °C)
Vapor pressure3.77 hPa (20 °C)
Solubility1000 g/l soluble
Dimensions
Materials Information
Toxicological Information
LD 50 oralLD50 Rat 3010 mg/kg
LD 50 dermalLD50 Rabbit 1500 mg/kg
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s)H226: Flammable liquid and vapour.
H312 + H332: Harmful in contact with skin or if inhaled.
H319: Causes serious eye irritation.
H360D: May damage the unborn child.
Precautionary Statement(s)P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P304 + P340 + P312: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313: IF exposed or concerned: Get medical advice/ attention.
Signal WordDanger
RTECSLQ2100000
Storage class3 Flammable liquids
WGKWGK 2 obviously hazardous to water
Disposal3
Relatively unreactive organic reagents should be collected in container A. If halogenated, they should be collected in container B. For solid residues use container C.
Safety Information
Categories of dangertoxic for reproduction, harmful, irritant
Product Usage Statements
Storage and Shipping Information
StorageStore at +2°C to +30°C.
Packaging Information
Transport Information
Declaration (railroad and road) ADR, RIDUN 2265 , 3, III
Declaration (transport by air) IATA-DGRUN 2265 , 3, III
Declaration (transport by sea) IMDG-CodeUN 2265 , 3, III
Supplemental Information
Specifications
Global Trade Item Number
Catalog Number GTIN
1109831000 04022536129280
1109832500 04022536129297

Related Products & Applications

Accessories (Primary)

Catalog Number Description
963533 Safety carrier

Accessories (Secondary)

Catalog Number Description
108801 Bottle key

Related Products By: Application Facete

Related Products By: Brand Facete

Categories

Reagents, Chemicals and Labware > Solvents > Solvents for Instrumental Organic Analysis > Solvents for Gas Chromatography, SupraSolv®
Analytics and Sample Preparation > Analytical Chromatography > Gas Chromatography GC > Solvents for Gas Chromatography, SupraSolv®