Millipore Sigma Vibrant Logo
Attention: We have moved. EMD Millipore products are no longer available for purchase on emdmillipore.com.Learn More

MFGB02GH3 Non-sterilized Millipak® Final Fill 20 Filter Unit 0.22  µm 1/4  in. HB/HB

View Products on Sigmaaldrich.com
MFGB02GH3
3  Double Easy-Open bag
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue NumberMFGB02GH3
Trade Name
  • Millipak®
DescriptionNon-sterilized Millipak® Final Fill 20 Filter Unit 0.22  µm 1/4  in. HB/HB
References
Product Information
Device ConfigurationCapsule
Connections, Inlet/Outlet6  mm (¼  in.) stepped hose barb inlet and outlet
Maximum Differential Pressure, bar (psid)Forward:60 psi (4.1 bar) at 25 °C; 50 psi(3.5 bar) at 25 °C; (5 µm) 25 psi (1.7 bar) at 80 °C; Reverse: 10 psi (0.7 bar) at 25 °C
Maximum Inlet Pressure, bar (psi)60 psi (4.1 bar) at 25 °C
Good Manufacturing PracticesThese products are manufactured in a facility which is certified to ISO® 9001:2015 Quality Management Systems.
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
MediaDurapore®
Sterilitynon-sterilized
SterilizationDevice integrity and retention was maintained after 3 autoclave cycles of 90 minutes at 126  °C. Devices can withstand a dose ≤ 40  kGy gamma exposure.
Bacterial RetentionQuantitative retention of 107 CFU/cm2 Brevundimonas diminuta ATCC® 19146 per AST® F838 methodology.
WettabilityHydrophobic
Physicochemical Information
Pore Size0.22 µm
Inlet ConnectionStepped Hose Barb
Outlet ConnectionStepped Hose Barb
Flow Rate0.51 L/min @ 0.69 bar ΔP
Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21 CFR 210.3 (b)(6), validated based on large volume parenteral specifications as detailed in USP <788> Particulate Matter in Injections
USP Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
Dimensions
Filtration Area100 cm²
Process Volume20 L
Inlet Connection Diameter1/4 in.
Outlet Connection Diameter1/4 in.
Materials Information
Chemistry
  • Polyvinylidene Fluoride (PVDF)
Device Material
  • Polysulfone
Support MaterialPolysulfone
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size3
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalog Number GTIN
MFGB02GH3 04054839378416

Documentation

Certificates of Quality

Title
Millipak Final Fill Capsule Durapore Membrane C2PB43981
Millipak Final Fill Capsule Durapore Membrane C0BB30053
Millipak Final Fill Capsule Durapore Membrane C3EB17623
Millipak Final Fill Capsule Durapore Membrane C9SA29234
Millipak Final Fill Capsule Durapore Membrane C2BB87441
Millipak Final Fill Capsule Durapore Membrane C4BB85684

Technical Info

Title
Improved Product Recovery using Blow-down and Millipak®Final Fill Filters
Reduce Contamination Risks and Simplify Filtration System Design and Operation

Data Sheet

Title
Durapore® Family Guide

Related Products & Applications