Millipore Sigma Vibrant Logo
Attention: We have moved. EMD Millipore products are no longer available for purchase on emdmillipore.com.Learn More

2500 ReBlot Plus Kit

View Products on Sigmaaldrich.com
2500
1 kit  
Purchase on Sigma-Aldrich

Overview

Replacement Information

Key Specifications Table

Key Applications
WB
Description
Catalogue Number2500
Brand Family Chemicon®
Trade Name
  • ReBlot
  • Chemicon
DescriptionReBlot Plus Kit
OverviewWestern blotting is a commonly used technique for studying protein function and localization. Typically, protein samples are electrophoresed on SDS-PAGE and transferred to a membrane such as nitrocellulose or nylon, where they are probed with specific antibodies. Unlike nucleic acid based technologies, which allow reuse of Southern and Northern blots, it has been difficult to reuse Western blots.

Stripping and re-probing of Western blots offers several advantages:

1) Conservation of samples that are expensive or available only in limited quantities,

2) Analysis of a given blot using several different antibodies, e.g. subtype- or isoform-specific antibodies,

3) Re-analysis of anomalous results and confirmation with the same or a different antibody,

4) Correcting errors in incubation with the wrong antibody,

5) Cost savings in reagents and time by reusing the same blot.

While antigen and antibody-based immunoaffinity matrices, such as Sepharose™ conjugates, have been reused many times without compromising antigen-antibody reactivity, the need for pH extremes and chaotropic agents has precluded the application of these methods to Western blotting.

The MILLIPORE Re-Blot Plus Western Blot Recycling Kit contains specially formulated solutions that quickly and effectively remove antibodies from Western blots without significantly affecting the immobilized proteins.

Advantages of the Re-Blot Plus Western Blot Recycling Kit include:

·*No pungent-smelling b-mercaptoethanol is contained in the Antibody Stripping Solution.

·*Antibody stripping is done at room temperature. No heating of blots is required.

·*Blots can be stripped of antibodies in approximately 15 minutes at room temperature.

·*Blots may be reused in 25 minutes.
Materials Required but Not Delivered· Standard Blot or blot strips, on nitrocellulose or PVDF/nylon membrane.

· Blocking Solutions.

· Plastic Wrap, such as Saran Wrap, for storage of blots that will not be re-probed immediately.

· Distilled Water, for reagent dilution.

· Plastic Trays for incubation of blots or blot strips in stripping, washing and blocking solutions.

· Positive and Negative Stripping Controls. It is recommended that one new strip (not subjected to stripping solution) be included for comparison purposes.
References
Product Information
Components
  • Mild Antibody Stripping Solution (10x) - (1 container, 50 mL).
  • Strong Antibody Stripping Solution (10x) - (1 container, 50 mL).
Detection methodChemiluminescence
Applications
Key Applications
  • Western Blotting
Application NotesThe MILLIPORE Re-Blot Plus Western Blot Recycling Kit is effective for removal of antibodies from Western blots that have been developed with chemiluminescence or radioactive iodine or other isotopes. It is not recommended for stripping colorimetric substrates (TMB, DAB, 4-chloronapthol, etc.), as it is not possible to effectively remove substrates that precipitate at the reaction site.

The Re-Blot Plus Western Blot Recycling Kit should be used only for qualitative purposes until it has been established by comparative blot analysis that stripping does not quantitatively affect a given antigen.

This product is for research use only; not for diagnostic or in vivo use.
Biological Information
Physicochemical Information
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Usage Statement
  • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Storage and Shipping Information
Storage ConditionsKit components should be stored at 4°C upon arrival. Product is stable for 3 to 6 months after receipt. If Antibody Stripping Solution crystallizes upon storage, it may be re-dissolved with gentle warming at 37°C before use.

Note: To prevent reagent degradation secure the cap tightly upon storage. Avoid extended exposure to air.
Packaging Information
Material Size1 kit
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalog Number GTIN
2500 04053252515460

Documentation

ReBlot Plus Kit SDS

Title

Safety Data Sheet (SDS) 

References

Reference overviewPub Med ID
Ghrelin and des-acyl ghrelin promote differentiation and fusion of C2C12 skeletal muscle cells.
Filigheddu, Nicoletta, et al.
Mol. Biol. Cell, 18: 986-94 (2007)  2007

Show Abstract
17202410 17202410
Prevention of neuron and oligodendrocyte degeneration by interleukin-6 (IL-6) and IL-6 receptor/IL-6 fusion protein in organotypic hippocampal slices.
Pizzi, Marina, et al.
Mol. Cell. Neurosci., 25: 301-11 (2004)  2004

Show Abstract
15019946 15019946
A 10-amino acid domain within human T-cell leukemia virus type 1 and type 2 tax protein sequences is responsible for their divergent subcellular distribution.
Meertens, Laurent, et al.
J. Biol. Chem., 279: 43307-20 (2004)  2004

Show Abstract
15269214 15269214

Data Sheet

Title
ReBlot Plus Kit - Data Sheet

User Guides

Title
Re-Blot Plus Western Blot Recycling Kit