Millipore Sigma Vibrant Logo

KVVLA10TT1 Opticap® XL10 Durapore® 0.1 µm 1-1/2 in. TC/TC

View Products on Sigmaaldrich.com
KVVLA10TT1
1  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information
      Description
      Catalogue NumberKVVLA10TT1
      ReplacesKVVL01TC1
      Trade Name
      • Opticap®
      DescriptionOpticap® XL10 Durapore® 0.1 µm 1-1/2 in. TC/TC
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaDurapore®
      SterilityOther
      Sterilization3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.1 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Air Diffusion at 23 °C≤20 mL/min @ 3.9 bar (56 psig) in water
      Bubble Point at 23 °C≥4830 mbar (70 psig) air with water
      Gravimetric ExtractablesThe extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length10 in. (25 cm)
      Length33.5 cm (13.2 in.)
      Diameter14.5 cm (5.7 in.)
      Filtration Area0.69 m²
      Inlet to Outlet Width33.5 cm (13.2 in.)
      Device Size10 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
      Global Trade Item Number
      Catalog Number GTIN
      KVVLA10TT1 04053252650932

      Documentation

      Operational Excellence Dossier

      Title

      Opticap® XL10 Durapore® 0.1 µm 1-1/2 in. TC/TC SDS

      Title

      Safety Data Sheet (SDS) 

      Certificates of Quality

      Title
      Opticap XL 10 Capsule Durapore Membrane C1HB08007Z
      Opticap XL 10 Capsule Durapore Membrane C7CA86695
      Opticap XL 10 Capsule Durapore Membrane C7NA80262
      Opticap XL 10 Capsule Durapore Membrane C8DA60150
      Opticap XL 10 Capsule Durapore Membrane C0DB56005
      Opticap XL 10 Capsule Durapore Membrane C0KB07465
      Opticap XL 10 Capsule Durapore Membrane C1MB70266Z
      Opticap XL 10 Capsule Durapore Membrane C1MB70269Z
      Opticap XL 10 Capsule Durapore Membrane C2DB48848Z
      Opticap XL 10 Capsule Durapore Membrane C7HA24862

      Technical Info

      Title
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters

      User Guides

      Title
      Opticap® XL Capsules and Opticap® XLT Capsules

      Related Products & Applications

      Product Families

      Related Products By: Brand Facete

      Categories

      Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Liquid > Durapore