Millipore Sigma Vibrant Logo

114561 Cyanide Cell Test

Overview

Replacement Information

Pricing & Availability

Catalog Number AvailabilityPackaging Qty/Pack Price Quantity
1145610001
Retrieving availability...
Limited Availability
Limited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

      EPS box 25 tests
      Retrieving price...
      Price could not be retrieved
      Minimum Quantity is a multiple of
      Maximum Quantity is
      Upon Order Completion More Information
      You Saved ()
       
      Request Pricing
      Description
      Catalogue Number114561
      OverviewThe method corresponds to DIN 38405-13 and is analogous to ISO 6703, EPA 335.2, APHA 4500-CN-E, and ASTM D2036-09 D.
      USEPA approved for wastewater.

      This Spectroquant® Cyanide Cell Test allows the accurate quantification of the free and readily liberated cyanide content in aqueous samples.

      Method applied: Cyanide ions react with a chlorinating agent to form cyanogen chloride which together with 1,3-dimethylbarbituric acid forms a violet dye (pyridine-free König reaction) that is determined photometrically.

      The Spectroquant® Cell Tests come with prefilled 16 mm round cells and all the required reagents to perform the analysis according to the instruction leaflet provided.

      All Spectroquant® Cell and Reagent Tests are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
      References
      Product Information
      HS Code3822 19 90
      Quality LevelMQ100
      Applications
      Biological Information
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Hazard Pictogram(s) Hazard Pictogram(s)
      Hazard Pictogram(s)
      Hazard Statement(s)H290: May be corrosive to metals.
      H314: Causes severe skin burns and eye damage.
      H335: May cause respiratory irritation.
      H412: Harmful to aquatic life with long lasting effects.
      Precautionary Statement(s)P234: Keep only in original packaging.
      P261: Avoid breathing mist or vapours.
      P273: Avoid release to the environment.
      P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
      P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
      P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
      Signal WordDanger
      Storage class8A Combustible, corrosive hazardous materials
      WGKWGK 2 obviously hazardous to water
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      StorageStore at +15°C to +25°C.
      Packaging Information
      Transport Information
      Declaration (railroad and road) ADR, RIDUN 3316 Chemie-Testsatz, 9, II
      Declaration (transport by air) IATA-DGRUN 3316 CHEMICAL KIT, 9, II
      Declaration (transport by sea) IMDG-CodeUN 3316 CHEMICAL KIT, 9, II
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalog Number GTIN
      1145610001 04022536155814

      Documentation

      Cyanide Cell Test SDS

      Title

      Safety Data Sheet (SDS) 

      Cyanide Cell Test Certificates of Analysis

      Product Number PackagingSpecificationLot Number
      1145610001 EPS boxPDF Specification Document

      Certificates

      Title
      114561 - Certificate of Quality - Spectroquant Cyanide Cell Test / Cyanid-Küvettentest / Test en cubetas Cianuros

      Technical Info

      Title
      Cyanide Spectroquant 114561 WW Comparison table 1999
      Cyanide Spectroquant 114561 WW Letter USEPA 1999
      Cyanide Spectroquant 114561 WW Method 1999

      Data Sheet

      Title
      Data Sheet (CoQ) - 1.14561

      User Guides

      Title
      Manual Spectroquant Multy - Operating manual
      Manual Spectroquant NOVA 30
      Quick Guide Spectroquant Photometer NOVA 60A (EN, DE, FR, ES, IT)
      User Guide (IFU) - 1.14561

      Related Products & Applications

      Accessories (Primary)

      Catalog Number Description  
      109137 Sodium hydroxide solution Show Pricing & Availability
      109072 Sulfuric acid Show Pricing & Availability
      109533 pH-indicator strips pH 5.0 - 10.0 Show Pricing & Availability
      110044 Cyanide Test Show Pricing & Availability
      114724 Empty cells 16 mm Show Pricing & Availability
      119533 Cyanide standard solution Show Pricing & Availability
      171201 Thermoreactor Show Pricing & Availability
      171202 Thermoreactor Show Pricing & Availability
      173016 Prove 100 Show Pricing & Availability

      Related Products By: Application Facete

      Related Products By: Brand Facete

      Categories

      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Waste Water > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Instrumental Test Systems for Quantitative Analyses > Photometric Measurements, Spectroquant® System > USEPA
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Instrumental Test Systems for Quantitative Analyses > Photometric Measurements, Spectroquant® System > Spectroquant® Tests
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Base Parameters from A to Z > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Environment > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Electroplating > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Groundwater, Surface Water > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Disposal Drainage Water > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Mineral Water > Cyanide