Our broad portfolio consists of multiplex panels that allow you to choose, within the panel, analytes that best meet your needs. On a separate tab you can choose the premixed cytokine format or a single plex kit.
Cell Signaling Kits & MAPmates™
Choose fixed kits that allow you to explore entire pathways or processes. Or design your own kits by choosing single plex MAPmates™, following the provided guidelines.
The following MAPmates™ should not be plexed together:
-MAPmates™ that require a different assay buffer
-Phospho-specific and total MAPmate™ pairs, e.g. total GSK3β and GSK3β (Ser 9)
-PanTyr and site-specific MAPmates™, e.g. Phospho-EGF Receptor and phospho-STAT1 (Tyr701)
-More than 1 phospho-MAPmate™ for a single target (Akt, STAT3)
-GAPDH and β-Tubulin cannot be plexed with kits or MAPmates™ containing panTyr
.
Catalog Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Select A Species, Panel Type, Kit or Sample Type
To begin designing your MILLIPLEX® MAP kit select a species, a panel type or kit of interest.
Custom Premix Selecting "Custom Premix" option means that all of the beads you have chosen will be premixed in manufacturing before the kit is sent to you.
If you have chosen panel analytes and then choose a premix or single plex kit, you will lose that customization.
Catalogue Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Species
Panel Type
Selected Kit
Qty
Catalog Number
Ordering Description
Qty/Pack
List Price
96-Well Plate
Qty
Catalog Number
Ordering Description
Qty/Pack
List Price
Add Additional Reagents (Buffer and Detection Kit is required for use with MAPmates)
Qty
Catalog Number
Ordering Description
Qty/Pack
List Price
48-602MAG
Buffer Detection Kit for Magnetic Beads
1 Kit
Space Saver Option Customers purchasing multiple kits may choose to save storage space by eliminating the kit packaging and receiving their multiplex assay components in plastic bags for more compact storage.
This item has been added to favorites.
The Product Has Been Added To Your Cart
You can now customize another kit, choose a premixed kit, check out or close the ordering tool.
Animal watering is done using either drinking bottles placed in each cage, or an automatic watering system. While animal feed quality is usually tightly controlled, the requirements for animal watering are less stringent. The US National Research Council Guide for the Care and Use of Laboratory Animals is recognized in many countries as the standard for quality animal care and use. It states that “Ordinarily animals should have continuous access to fresh, potable, uncontaminated drinking water, according to their particular requirements.”
While ordinary tap water can be used for animal watering in some cases, the fact that its composition may vary with time and with the seasons can be a problem for researchers. Tap water variations may also be an issue when comparing the results of research performed in laboratories located in different geographical locations. In order to obtain consistent and reliable experimental results, it is important to provide laboratory animals with drinking water of consistent quality. In addition, some animals (for example, immuno-compromised animals) or disease models are known to be very sensitive to their environment and require very pure water.
The following water contaminants should be avoided:
Organics Some organics, such as pesticides, endocrine disrupters, etc. which may be present in tap water, can affect the health of laboratory animals and interfere with the research being conducted. In addition, in the presence of chlorine, organics may form disinfection by-products (DBP), some of which are thought to be carcinogenic or affect reproduction. Organics can also be used as nutrients by bacteria, and lead to bacterial proliferation. Organics can be removed by activated carbon and reverse osmosis technologies.
Bacterica Bacteria can cause serious health problems to the animals and are a main concern in animal facilities. Immuno-compromised and transgenic animals are especially sensitive to bacterial contamination. Pseudomonas aeruginosa, for example, is an opportunistic pathogen commonly found in water, and may affect the health of vulnerable animals. Bacteria levels in water can be minimized by reverse osmosis.
Heavy metals High levels of heavy metals (copper, iron, zinc, lead …) can be toxic for health-compromised animals. These metals can be leached from piping. Ions and metals present in water can be greatly removed by reverse osmosis.
Hardness and particles Hard water deposits and particles can damage the valves of automated watering systems, and cause leaks inside the animal cages. They will also increase the need for system maintenance.
In conclusion, water purified by reverse osmosis is usually recommended for this application, as it removes most of the organics and ions present in the feed water, and provides a consistent water quality. Tap water composition may vary with time and with the seasons, and should not be used for laboratory animals. Deionized water, purified with ion exchange resins, may contain organics and microorganisms, and is therefore not recommended.
Reverse osmosis water is usually treated before being used to water laboratory animals, in order to minimize the risks of bacterial contamination within the animal facility. Ozone treatment or ultra-violet irradiation may be used, but the most commonly methods are chlorination and acidification.
Chlorination Chlorination is commonly used. Water pH should be regularly controlled, as chlorination is less effective at high pH. Accepted practice is to reach a residual range of free chlorine between 5 and 12 ppm.
Acidification Acidification is more stable and lasts longer in the system than chlorine. The disadvantage of chlorination is that corrosion-resistant materials must be used. The pH range should be between 2.6 and 3 in order to be effective. The animals may refuse to drink the water if the pH is 2.5 or lower because of poor taste.
References
You may find more information related to laboratory animals in the following web sites:
Your opinion is important for us. Please let us know if the information provided was useful, if there is missing information that you would like to see or if you have experience that you would like to share with us on this topic. Please contact us by e-mail, send us feed back and we will come back to you. Contact us.