      Description
      Catalogue NumberKPGEA1TTT1
      Trade Name
      • Millipore Express®
      DescriptionOpticap® XLT 10 Millipore Express® PHF Autoclavable 0.2 µm 1-1/2 in. TC
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring seal
      Housing MaterialPolypropylene (PP)
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      T-line/Gauge PortT-line
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® PHF
      Sterilization3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
      Bacterial RetentionSamples of membrane used in this filter were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.2 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Air Diffusion at 23 °C≤30 mL/min @ 2.8 bar (40 psig) in water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Differential Pressure5500 mbar (80 psi) @ 25 °C; 1000 bar (15 psi) @ 80 °C
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 10 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length10 in. (25 cm)
      Length37.6 cm (14.8 in.)
      Diameter10.7 cm (4.2 in.)
      Filtration Area0.54 m²
      Inlet to Outlet Width15.2 cm (6.0 in.)
      Device Size10 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene/Polysulfone
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
      Global Trade Item Number
      Catalog Number GTIN
      KPGEA1TTT1 04055977294958

      Documentation

      Certificates of Quality

      Title
      Opticap XL 10 Capsule Millipore Express PHF Membrane C9SA84344
      Opticap XLT 10 Capsule Millipore Express PHF Membrane C2NB31217
      Opticap XLT 10 Capsule Millipore Express PHF Membrane- C4EB23508

      Technical Info

      Title
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
      Extended bacterial retention testing of Millipore Express® 0.2 μm filters in a continuous flow system

      Data Sheet

      Title
      Millipore Express®PHF Hydrophilic Filters

      User Guides

      Title
      User Guide - Filters with Millipore Express®Membrane